Searchable abstracts of presentations at key conferences in endocrinology
Endocrine Abstracts (2023) 95 P17 | DOI: 10.1530/endoabs.95.P17

Mid Yorkshire Teaching NHS Trust, Wakefield, UK


Background: There is clear evidence that achieving optimal glycaemic control in type 1diabetes reduces the complications of diabetes. Increased technology use is associated with lower HbA1c. NICE target HbA1c is 48 mmol/mmol.

Objective: Are there differences in HbA1c between patients with Type 1 diabetes using continuous glucose monitoring sensor (CGM) or hybrid closed loops in real world setting in paediatric patients at Mid Yorkshire Teaching NHS Trust?

Method: Compare the most recent HbA1c in September 2022 with HbA1c from 2021 for 313 of patients with Type 1 diabetes aged 0–18 years under the MY Paediatric diabetes service.

Results: 57% of patients were on injections, 21% on pump and 22% on pump with closed loop. For glucose monitoring, 55% use CGM, 37% Libre and 7% use finger prick glucose testing. We found that HbA1c improved with CGM across all age groups (by up to 10%). The biggest reduction in HbA1c was seen in groups using injections with CGM and those with using hybrid closed loop system.

Table 1 HbA1c improvement after using continuous glucose monitoring
Mean HbA1c (mmol/mmol)
Age (yr)BaselineEnd-pointDifferenceImprovement
<581.8662.2919.5723.91%
5–971.0858.7612.3217.33%
10–1474.6863.5811.1014.86%
15–1972.5867.025.567.66%
Total73.2464.029.2312.60%
Table 2 Median HbA1c difference among different groups
BaselineEnd-pointDifferenceImprovement
Group 1 – Insulin Injection6265−3−4.03%
Group 2 – Injection + libre696545.11%
Group 3 – Injection + CGMS716479.22%
Group 4 – Pump + Libre646046.30%
Group 5 – Pump + CGMS (without Closed-Loop)605646.67%
Closed-Loop625758.06%

Conclusion: CGM and hybrid closed loop systems improve HbA1c. Following updates to local commissioning policy in line with NICE guidance on use of CGM all children and young people under the care of MY Paediatric Diabetes service will be encouraged to use CGM. We await the NICE Technology Appraisal on hybrid closed loop systems.HbA1c improvement after using continuous glucose monitoringMedian HbA1c difference among different groups

Volume 95

50th Annual Meeting of the British Society for Paediatric Endocrinology and Diabetes

Manchester, UK
08 Nov 2023 - 10 Nov 2023

British Society for Paediatric Endocrinology and Diabetes 

Browse other volumes

Article tools

My recent searches

No recent searches.

My recently viewed abstracts